Glossary entry (derived from question below)
angielski term or phrase:
Vent Steam Condenser
polski translation:
skraplacz mieszaniny parowo-powietrznej
- The asker opted for community grading. The question was closed on 2010-10-24 10:54:08 based on peer agreement (or, if there were too few peer comments, asker preference.)
Oct 20, 2010 16:52
14 yrs ago
12 viewers *
angielski term
Vent Steam Condenser
angielski > polski
Technika/inżynieria
Energia elektryczna/energetyka
turbiny parowe
"The vacuum pressure in this system is provided by the existing Vent Steam condenser (VSC). Steam that enters the vent steam condenser is condensed, and the non-Condensable gas (air) is blown out by a Jet Steam Ejector. "
Czy chodzi o skraplacz pary z odpowietrznikiem?
Czy chodzi o skraplacz pary z odpowietrznikiem?
Proposed translations
(polski)
5 | skraplacz pary z dławnic |
Agnieszka Chojnacka
![]() |
Proposed translations
21 min
Selected
skraplacz pary z dławnic
Normalnie wszyscy dostawcy turbin piszą gland steam condenser, a ten tekst chyba jest od Skody i oni piszą vent.
Jet steam ejector, to smoczek parowy.
Jet steam ejector, to smoczek parowy.
Note from asker:
Niestety w tekście jest zarówno gland steam condenser, jak i vent steam condenser. Do pierwszego dostarczana jest para z obwodu odprowadzania pary z dławnic turbiny wysokociśnieniowej do dławnic turbiny niskociśnieniowej. Drugi skraplacz jest jak widać częścią układu odpowietrzania. |
4 KudoZ points awarded for this answer.
Comment: "Dziękuję"
Discussion
http://tinyurl.com/3yuzudq
Podejrzewam, że vent steam do para napowietrzona, nie odpowietrzona, więc chodzi o kondensator pary napowietrzonej.
One circuit controls the steam pressure. It connects the front and rear turbine glands, and insures the steam extraction from the HP glands and the steam feeding of the LP vacuum glands. The pressure level in this circuit is slightly above atmospheric pressure (approximately 1.02 bar). Two gland steam valves achieve the pressure control. One valve delivers steam into the circuit during start-up of the turbine. The other valve relieves excess steam, typically when the quantity of steam extracted from the HP glands is higher than the quantity of steam fed into the LP vacuum glands. This condition occurs during all operational modes when there is a higher steam inlet. Steam delivered into the gland steam circuit during start-up or shut down is taken from a steam header. Steam extracted from the circuit is passed into the existing Gland Steam Condenser (GSC).